23] torque filter time constant (parameter no.33), 24] press velocity (parameter no.34), 25] safety velocity (parameter no.35) – IAI America MSCON User Manual

Page 271

Advertising
background image

Chapter 7 Parameter

263

[23] Torque filter time constant (Parameter No.33)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

33 Torque Filter Time Constant

TRQF

-

0 to 2500

In accordance

with actuator

This parameter decides the filter time constant for the torque command. When vibrations

and/or noises occur due to mechanical resonance during operation, this parameter may be

able to suppress the mechanical resonance. This function is effective for torsion resonance of

ball screws (several hundreds Hz).

[24] Press velocity (Parameter No.34)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

34 Push Velocity

PSHV

mm/s

[deg/s]

1 to actuator's max.

pressing speed

In accordance

with actuator

This is the parameter to set the velocity in pressing operation.

The setting is done considering the actuator type when the product is delivered. [Refer

Appendix to 9.1 List of Specifications of Connectable Actuators]

If a change to the setting is required, make sure to have the setting below the maximum

pressing velocity of the actuator. Setting it fast may disable to obtain the specified pressing

force. Also when setting at a low velocity, take 5mm/s as the minimum. Specified pressing force

may not be obtained also when a low speed setting is set.

Positioning Velocity

Press Velocity

Positioning width

Work

Velocity

Caution: If the velocity of the positioning of the position table is set below this

parameter, the pressing speed will become the same as the positioning

speed.

[25] Safety velocity (Parameter No.35)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

35 Safety Velocity

SAFV

mm/s

[deg/s]

1 to 250 (maximum

speed for the

actuators with 250

or less)

100

This is the parameter to set the maximum speed of manual operation while the safety velocity

selected in the teaching tool. Do not have the setting more than necessary.

Advertising