4 fieldbus type address map – IAI America MSCON User Manual

Page 114

Advertising
background image

3.4 Fieldbus

Type

Address Map

106

PLC Input (m is PLC input top word address for each axis number).


Address m

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Current

Position

(Lower word)




Address m+1

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Current

Position

(Upper word)

(Note)If the target position is a negative value, the output is made with two’s implement.




Address m+2

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Command

Current

(Lower word)

32,768

16,384

8,192

4,096

2,048

1,024

512

256

128

64

32

16

8

4

2

1




Address m+3

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Command

Current

(Upper word)

524,288

262,144

131,072

65,536




Address m+4

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Current Speed

(Note)It will be expressed with two’s implement for a negative value.




Address m+5

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Unavailable




Address m+6

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Alarm Code




Address m+7

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Status Signal

E

M

G

S

CRDY

ZO

N

E

2

ZO

N

E

1

MEND

B

A

LM

P

S

FL

S

V

A

LM

M

O

V

E

HEND

P

E

N

D



1 word=16 bit