4 fieldbus type address map – IAI America MSCON User Manual

Page 135

Advertising
background image

3.4 Fieldbus

Type
Address Map

127

Set the parameter No.25 of MSCON

Solenoid valve mode 1

Solenoid valve mode 2

4

5

Category

Port

No.

Symbol

Signal Name

Symbol

Signal Name

0

ST0

Start position 0

ST0

Start position 0

1

ST1

Start position 1

ST1

Start position 1

2

ST2

Start position 2

ST2

Start position 2

3

ST3

Start position 3

4

ST4

Start position 4

5

ST5

Start position 5

6

ST6

Start position 6

7

8

Unavailable

Unavailable

9

BKRL

Brake release

BKRL

Brake release

10

Unavailable

Unavailable

11

HOME

Home return

12

*STP

Pause

13

Unavailable

Unavailable

14

RES

Reset

RES

Reset

PLC outputψ

MSCON input

15

SON

Servo ON command

SON

Servo ON Command

0

PE0

Position 0 complete

LS0

Retrieval to the Edge

Commands 0

1

PE1

Position 1 complete

LS1

Retrieval to the Edge

Commands 1

2

PE2

Position 2 complete

LS2

Retrieval to the Edge

Commands 2

3

PE3

Position 3 complete

4

PE4

Position 4 complete

5

PE5

Position 5 complete

6

PE6

Position 6 complete

Unavailable

7

ZONE1

Zone 1

ZONE1

Zone 1

8

PZONE/

ZONE2

Position zone/

Zone 2

PZONE/

ZONE2

Position zone/

Zone 2

9

Unavailable

Unavailable

10

HEND

Home return

completion

HEND

Home return

completion

11

PEND

Positioning completion

signal

Unavailable

12

SV

Operation preparation

end

SV

Operation preparation

end

13

*EMGS

Emergency stop

*EMGS

Emergency stop

14

*ALM

Alarm

*ALM

Alarm

MSCON output

ψ

PLC input

15

*BALM

Absolute battery

voltage drop alarm

*BALM

Absolute battery

voltage drop alarm

(Note): “*” in codes above shows the signal of the active low.