3.8 C

ontrol and functions of Input and output signals of Remote I/O Mode

207

[6] Pause and operation interruption (ST*, *STP, RES, PE*, PEND)

Pause is possible during movement. In this mode, the following two methods are possible for

pause.

1) Use of pause signal *STP

Turning reset signal RES ON during the pause allows the remaining moving distance to be

cancelled to interrupt the operation.

2) Use of start signal ST*

This method is valid when Parameter No.27 “Move command type” is set to “0” (factory

setting). The actuator can only be moved while the ST* signal is set to ON and stopped if ST*

is turned OFF. Since setting the ST* signal to OFF is assumed as interrupt of operation, the

remaining moving distance may not be cancelled.

(1) Use of pause signal *STP

Pause input signal

Velocity

Time

Position 1 input

input Start

signal

(Move start)

Moving

comp.

Positioning

Completion

Signal Output

2)

3)

1)

4) 5)

ON

OFF

2)

3)

1)

4)

5)

Deceleration

and stop with

pause turned

OFF

Movement

restart with

pause turned

ON

Stop

status

Acceleration

Deceleration

Acceleration

Deceleration

„

Control method

The pause signal is an input signal always set to ON. So, it is normally used to remain ON. Use

this function for interlock in case where an object is invaded into the moving direction of the

actuator being moved.

1) If pause signal *STP is turned OFF during operation of the actuator, the actuator is

decelerated to a stop. The deceleration is defined by the value set in the position table.

2) During pause, current position No. PE* and positioning complete signal PEND are not turned

ON.

3) If pause signal *STP is returned to ON, the actuator continues the remaining movement. The

acceleration is the value set in the position table.

4) Turning reset signal RES ON during pause (*STP being ON) allows the remaining movement

to be canceled to interrupt the operation.

Before operation

Positioning complete state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Turning RES ON here allows

continuous operation to be cancelled

Pause Signal*STP

(PLCoMSCON)

Positioning Completion Signal

PEND

(MSCONoPLC)

Operation of actuator

PEND turned

OFF

PEND and PE

not turned ON

Current Position No.

PE*

(MSCONoPLC)

Advertising