4 fieldbus type address map – IAI America MSCON User Manual

Page 141

Advertising
background image

3.4 Fieldbus

Type
Address Map

133

7) Writing of Pressing Current Limit

PLC Output (Address n is the input and output top address for MSCON Gateway Unit.)

(Note) If the writing is finished in normal condition, the same content as the demand command

is returned to the response command. If an error is generated, an error response is

returned. [Refer to this Section 16).]



Bit

Address

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

n+2

Demand

Command

[1007h]

0

0

0

1

0

0

0

0

0

0

0

0

0

1

1

1

n+3

Data 0

[Position No.]

128

64

32

16

8

4

2

1

n+4

Data 1

[Pressing

Current Limit]

128

64

32

16

8

4

2

1

n+5

Data 2

[0]

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

W

rit

in

g o

f P

re

ss

in

g C

ur

re

nt

L

im

it

n+6

Data 3

[Axis No.]

4

2

1



1 word=16 bit