5 control signals for positioner 1 mode – IAI America MSCON User Manual

Page 106

Advertising
background image

3.4 Fieldbus

Type

Address Map

98

3.4.5 Control Signals for Positioner 1 Mode

To select the mode, use Gateway Parameter Setting Tool. This is the method to operate with

the operational condition of the indicated position number.

The settable No. of position data items is max 256 points.

The main functions of MSCON capable to control in this mode are as described in the following

table.

{

: Direct control

ٌ

: Indirect control

×: Disable

ROBO cylinder function

Positioner 1 Mode

Remarks

Home-return operation

{

Positioning operation

ٌ

Speed and

acceleration/deceleration

setting

ٌ

Pitch feeding (Incremental)

ٌ

Pressing operation

ٌ

Speed change during

Movement

ٌ

Operation at different

acceleration and

deceleration

ٌ

These items must be set in the position data

table.

Pause

{

Zone signal output

{

PIO pattern selection

×



(1) PLC Address Composition

(m is PLC input and output top word address for each axis number)

PLCĺMSCON (PLC Output)

MSCONĺPLC (PLC Input)

Unavailable

m to m+1

Current Position

m to m+1

Specified Position No.

m+2

Completed Position No.

(Simple Alarm Code)

m+2

Control Signal

m+3

Status Signal

m+3

[Refer to Section 3.4.2 for the address maps for each Fieldbus.]




This mode is not applicable for CompNet and MECHATROLINK specifications.