Chapter 1 Specifications Check

29

1.4.3 Specifications of PROFIBUS-DP Interface

Item

Specification

Communication

Protocol

PROFIBUS-DP

Baud Rate

Automatically follows the master

Communication

System

Hybrid System (Master-Slave System or Token Passing System)

Number of

Occupied Stations

Refer to 3.4.1 PLC Address Construction by each Operation Mode

Max. Total Network Length

Baud Rate

Cable Type

100m

12,000/6,000/3,000kbps

200m

1,500kbps

400m

500kbps

1000m

187.5kbps

Communication

Cable Length

1200m

9.6/19.2/93.75kbps

Type A Cable

Communications

Cable

STP cable AWG18

Connector

(Note1)

9 pin female D-sub Connector

Transmission Path

Format

Bus/Tree/Star

Note 1: Prepare the 9-pin male D-sub connector as the connector on the cable side.

1.4.4 Specifications of CompoNet Interface

Item

Specification

Communication System

CompoNet specialized protocol

Communication Type

Remote I/O Communication

Baud Rate

Automatically follows the master

Communication Cable Length

Follows CompoNet Type

Slave Type

Word Mixed Slave

Available Node Addresses for

Setting

0 to 63 (Setting conducted on controller parameter)

Number of Occupied Channels Refer to 3.4.1 PLC Address Construction by each Operation Mode

Communications cable

(Note1)

Round-type cable (JIS C3306, VCTF2 conductors)

Flat cable I (with no sheathed)

Flat cable II (sheathed)

Connector (Controller side)

XW7D-PB4-R manufactured by OMRON or equiv.

Note1: Prepare a communication cable separately.