Chapter 6

Absolute Reset and

Absolute Battery

242

(2) For CON-PTA/PDA/PGA

1)

Press Reset Alm.

2)

Press Trial Operation on the Menu 1 screen.

3)

Press Jog_Inching on Trial screen.

4)

Press Home on Job/Inching screen.

Adjustment for Repeatability of Home Position

In case the home position has changed from where it was previously in an absolute reset after

the absolute data has lost, it can be adjusted in Parameter No. 22 Home Return Offset.

Mark the home position on the mechanical side at the first startup. From the position where it

has changed from the original home position after the absolute reset, move the actuator to the

marked position with such an operation as JOG operation. Read the coordinates and add (if the

number is positive, and subtract if negative) them to the values in Parameter No. 22.

(Note) At this time, note the values in Parameter No. 22 before the adjustment so the setting

can be put back in any occasions.