IAI America MSCON User Manual

Page 164

Advertising
background image

3.7

Control and functions of Input and output signals of Modes other than Remote I/O Mode

Power Supply and Cutof

f

156

(11) Jog-speed/inch-distance switching (JVEL) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

{

{

{

Ч

{

Ч

It is a signal to switch the parameters to indicate the speed or inching (incremental) distance

when in JOG operation and inching operation. Table below shows the relations.

JVEL signal

Jog operation : JISL=OFF

Inch operation : JISL=ON

OFF

Parameter No.26, “Jog speed”

Parameter No.26, “Jog speed”

Parameter No.48, “Inch distance”

ON

Parameter No.47, “Jog speed 2”

Parameter No.47, “Jog speed 2”

Parameter No.49, “Inch distance 2”



(12) Jog/inching switching (JISL) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

{

{

{

Ч

{

Ч

This signal changes over the jog operation and the inching (incremental) operation.

JISL = OFF : Jog operation

JISL = ON : Inching operation

When the JISL signal is turned ON (for inching operation) during the jog operation, the actuator

is decelerated and performs the inching operation.

When the JISL signal is turned OFF (jog) while the actuator is moving by inching, the actuator

will complete the movement and then switch to the jog function.

Jog operation

Inching operation

JISL

OFF

ON

Speed

Parameter No.26, “Jog speed”

Parameter No.26, “Jog speed”

Movement

distance

Parameter No.48, “Inch distance”

JVEL

= OFF

Acceleration/

deceleration

Rated value (The specific value varies

depending on the actuator.)

Rated value (The specific value varies

depending on the actuator.)

Speed

Parameter No.47, “Jog speed 2”

Parameter No.47, “Jog speed 2”

Movement

distance

Parameter No.49, “Inch distance 2”

JVEL

= ON

Acceleration/

deceleration

Rated value (The specific value varies

depending on the actuator.)

Rated value (The specific value varies

depending on the actuator.)

Operation

When the JOG +/JOG – signal is ON. Upon detection of the leading (ON edge)

of the JOG +/JOG - signal.



Advertising