3.4 Fieldbus

Type

Address Map

122

(2) Input and Output Signal Assignment for each Axis

The I/O signals for each axis consists of 1 words for each I/O bit register.

Ɣ The control signals and status signals are ON/OFF signals in units of bit.

Ɣ For the indicated position number and complete position number, 8-bit binary data is

available and values from 0 to 255 can be used.

PLC Output (m is PLC output top word address for each axis number)


Address m

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Control

Signal/

Specified

Position No.

B

K

R

L





SON

R

E

S

S

TP

HOME

CSTR

PC128

PC64

PC32

PC16

P

C

8

P

C

4

P

C

2

P

C

1


PLC Input (m is PLC Input top word address for each axis number)


Address m

b15 b14 b13 b12 b11 b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

b0

Status

Signal/

Completed

Position No.

E

M

G

S

ZO

N

E

1

P

S

FL

S

V

A

LM

M

O

V

E

HEND

P

E

N

D

P

M

12

8

P

M

64

P

M

32

P

M

16

P

M

8

P

M

4

P

M

2

P

M

1


Caution: Set the operational condition in advance with using a teaching tool such as PC

software in the position number to be used. Selecting a position number with no

setting conducted will generate the alarm code 0A2 “Position Data Error”.

1 word=16 bit

Control Signal

Specified Position No.

Status Signal

Completed Position No.

1 word=16 bit