IAI America MSCON User Manual

Page 253

Advertising
background image

Chapter 6

Absolute Reset and

Absolute Battery

245

6.2.2 Replacement of absolute battery

For the battery replacement, remove the battery connector while keeping the power to the

controller ON, and change the battery installed in the battery holder.

 

Caution: To replace the old absolute battery with a new one with the controller

power being off, complete the replacement within 15 minutes from the

removal of the old battery if it is before the alarm is generated. The

absolute data may get lost if it exceeds 15 minutes.

[1] Absolute battery unit

Absolute battery unit consists of three components. [Refer to the diagram below]














Battery Cover

Battery (AB-5)

Battery Clip



y

Assembled Condition














[2] Detachment

1) Unplug the connector for battery connection off the battery connector on the front panel of

MSCON.

2) Hold the point to detach the absolute battery unit and pull the absolute battery unit off

towards you.

[3] Attachment

1) Push the absolute battery unit along the attachment frame on the bottom of MSCON until it

makes a click noise.

2) Plug the connector for battery connection to the battery connector on the front panel of

MSCON. [Refer to 2.4.4 Battery Connection.]

Point to hold when

detaching the

absolute battery

unit from MSCON.

Connector for Battery Connection

Point to hold when separating the

absolute battery unit to battery cover

and battery clip.