IAI America MSCON User Manual

Page 213

Advertising
background image

3.8 C

ontrol and functions of Input and output signals of Remote I/O Mode

205

 

Caution: (1) The speed during tension operation is set in Parameter No.34. [Refer to

9.1 List of Specifications of Connectable Actuators for the pressing speed.]

Do not set any value larger than the value in the list. If the speed set in the

position table is equal to or less than the tension speed, the tension

operation is performed at the setup speed.

(2) The tension ready position should be the tension start position or forward. If

not, the moving direction varies depending on the start position to be

dangerous.

The tension operation from a coordinate (less than 30mm = 80 – 50 in the

above example) located before the end position (30mm or less) changes to

the pressing operation from the current position to the tension end position.

Note that the tension operation after positioning to the position of 80mm

does not take place.

(3) The work is pulled also after completion of the tension. The work is drawn

back or pulled further if the work is moved. When the work is drawn back

before the approach position, alarm code 0DC “pressing operation range

error” occurs to stop the work. When the work is moved in the tension

direction and the load current becomes less than the current limit value

(pressing in [%]), PEND is turned OFF. Naturally, the work reaches the

tension moving distance set in “Positioning width” to cause miss-pressing.

(4) Tension operation cannot be performed with the rotary actuator.

Pressing Operation

ST*: Start position

ST*

ST*

ST*

Tension Operation

Approach Operation

Tension Operation

Tension start position

80mm

Tension end position

80 – 50 = 30mm

Advertising