Chapter 1 Specifications Check

37

(4) Heat Radiation and Installation

Design and Build the system considering the size of the controller box, location of the controller

and cooling factors to keep the ambient temperature around the controller below 40qC

Pay a special attention to the battery unit since the performance of it would drop both in the low

and high temperatures. Keep it in a room temperature environment as much as possible.

(Approximately 20qC is the recommended temperature.)

To install the unit, use the attachment holes on the top and bottom of the main body and affix

with screws, or attach to DIN rails. (Regenerative resistance unit is separated to screw

attachment type and DIN rail attachment type. Have an appropriate way to affix the unit for

each type.)

20mm or more

50mm or more

20mm

or more

20mm or more

30mm

or more

20mm or more

10mm or more

10mm

or more

50mm or more

150mm or more

Waste

Heat