IAI America MSCON User Manual

Page 286

Advertising
background image

Chapter 7 Parameter

278

[85] Total movement count threshold (Parameter No.147)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

147 Total Movement Count Threshold

TMCT

Times

0 to 999999999

0 (Disabled)

An alarm is generated when the total movement count exceeds the value set to this parameter.

The judgment would not be made if the value is set to 0.

[86] Total operated distance threshold (Parameter No.148)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

148 Total Operated Distance

Threshold

ODOT

m

0 to 999999999

0 (Disabled)

An alarm is generated when the total operation distance exceeds the value set to this

parameter.

The judgment would not be made if the value is set to 0.

[87] Zone output changeover (Parameter No.149)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

149 Zone Output Changeover

FPIO

-

0: Not to change

1: To change

0

In Remote I/O Mode, the effective zone signals are determined by the setting of this parameter

and the setting of Parameter No.25 PIO Pattern Select.

The relationship between the parameter settings and effective zone signal outputs are as

shown in the table below.

Parameter No.149

Zone Output Changeover

Operation

Mode

Parameter No.25

PIO pattern selection

0

1

0

ZONE1

PZONE

ZONE1

ZONE2

1

2

PZONE

ZONE1

4

Remote I/O

Mode

5

ZONE1

PZONE

ZONE1

ZONE2

[88] Linear absolute home preset value (Parameter No.150)

This is the parameter for the future extension. Do not attempt to change the initial settings.

[89] Light error alarm output select (Parameter No.151)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

151 Light Error Alarm Output Select

FSTP

-

0: Battery voltage

drop warning

output

1: Output of battery

voltage drop

warning or

message-level

alarm

0

It can be selected if an output is to be made when a message-level alarm is generated as well

as when the battery voltage drop error is occurred for the output condition of BALM signal.