Chapter 7 Parameter

251

Parameter List (continued)

No.

C

at

eg

or

y

Name

Symbol Unit

(Note 1)

Input Range

Default factory

setting

Relevant

sections

105 C

Damping

Characteristic

Coefficient 1

DC11

-

0 to 1000

10

4.2

106 C

Damping

Characteristic

Coefficient 2

DC21

-

0 to 1000

1000

4.2

107 B

Natural Frequency

NP01

1/1000Hz

500 to 30000

10000

4.2

108 C

Vi

br

at

io

n s

up

pr

es

s

paramete

r set 3

Notch Filter Gain

NFG2

-

1 to 20000

9990

4.2

109 B Default Vibration Suppress

No.

CTLF

-

0 to 3

0

4.2

110 B Stop Method at Servo OFF

FSTP

-

0: Rapid stop

1: Deceleration to

stop

0

4.2

112 B Monitoring Mode Selection

FMNT

-

0: Unused

1: Monitor

Function 1

2: Monitor

Function 2

3: Monitor

Function 3

1

7.2 [59]

113 B Monitoring Period

FMNT

msec

1 to 100

1

7.2 [60]

117 B Automatic Loadcell

Calibration at Start

FFRC

118 B

Pressing Operation without

Completion of Loadcell

Calibration

FFRC

119 B Loadcell Calibration Time

CLBT

For future

extension use.

Unavailable

120 C Servo Gain Number 1

PLG1

-

0 to 31

In accordance

with actuator

(Note 2)

7.2 [5]

7.3

121 C Feed Forward Gain 1

PLF1

-

0 to 100

In accordance

with actuator

(Note 2)

7.2 [41]

122 C Velocity Loop Proportional

Gain 1

VLG1

-

1 to 27661

In accordance

with actuator

(Note 2)

7.2 [21]

7.3

123 C Velocity Loop Integral Gain 1

VLT1

-

1 to 217270

In accordance

with actuator

(Note 2)

7.2 [22]

7.3

124 C Torque Filter Time Constant 1

TRF1

-

0 to 2500

In accordance

with actuator

(Note 2)

7.2 [23]

7.3

125 C Current Control Width

Number 1

CLP1

0 to 4

In accordance

with actuator

(Note 2)

7.2 [35]

7.3

126 C Servo Gain Number 2

PLG2

-

0 to 31

In accordance

with actuator

(Note 2)

7.2 [5]

7.3

127 C Feed Forward Gain 2

PLF2

-

0 to 100

In accordance

with actuator

(Note 2)

7.2 [41]

128 C Speed Loop Proportional

Gain 2

VLG2

-

1 to 27661

In accordance

with actuator

(Note 2)

7.2 [21]

7.3

129 C Speed Loop Integral Gain 2

VLT2

-

1 to 217270

In accordance

with actuator

(Note 2)

7.2 [22]

7.3

130 C Torque Filter Time Constant 2

TRF2

-

0 to 2500

In accordance

with actuator

(Note 2)

7.2 [23]

7.3

Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.