273

[56] Damping characteristic coefficient 1, 2 / Natural frequency / Notch filter gain

(Parameter No.97 to No.108)

This parameter is exclusively used for vibration suppress control.

Name

Parameter No.

Damping characteristic coefficient 1

97

Damping characteristic coefficient 2

98

Natural frequency

99

Parameter set 1

Notch filter gain

100

Damping characteristic coefficient 1

101

Damping characteristic coefficient 2

102

Natural frequency

103

Parameter set 2

Notch filter gain

104

Damping characteristic coefficient 1

105

Damping characteristic coefficient 2

106

Natural frequency

107

Parameter set 3

Notch filter gain

108

[Refer to Chapter 4 Vibration Suppress Control Function (Option) for details.]





[57] Default vibration suppress No. (Parameter No.109)

This parameter is exclusively used for vibration suppress control.

[Refer to Chapter 4 Vibration Suppress Control Function (Option) for details.]

[58] Stop method at servo OFF (Parameter No.110)

This parameter defines how to stop the actuator at issue of servo OFF command, emergency

stop or occurrence of an error (operation release level).

Set Value

0

1

Stop Command

In Anti-Vibration

Control Process

In Normal

Position Control

Process

In Anti-Vibration

Control Process

In Normal

Position Control

Process

Pause

Vibration Control

Deceleration and

Stop

Normal

Deceleration and

Stop

Servo OFF

Emergency Stop

Error (Operation

Cancellation Level)

Sudden stop due to emergency

stop torque

Vibration Control

Deceleration and

Stop

Normal

Deceleration and

Stop

Error (Cold Start)

Sudden stop due to emergency stop torque

Advertising