3.8 Control and functions of Input and output signals of Remote I/O Mode

216

[5] Pause and Operation Interruption (ST*, *STP, RES, PE*, PEND)

Turning start signal ST* OFF allows the actuator to be paused while it is moved. To restart it,

turn the same ST* signal ON.

Stop

status

Start signal

Velocity

Time

Input start

signal for

position 1

(Moving start)

Moving

comp.

Positioning

Completion

Signal Output

Deceleration

2)

3)

1)

4) 5)

ON

OFF

Decelerate and

stop by start signal

input to Position 1

being OFF

Movement

resumed

by start signal

input to Position 1

being ON

Acceleration

Deceleration

Acceleration

2)

3)

1)

4)

5)

„

Control method

If start signal ST* is turned OFF during movement, the actuator can be paused.

Use the control method for interlock in case where an object is invaded into the moving

direction of the actuator being moved.

1) If the ST* signal is turned OFF during movement, the actuator is decelerated to a stop. The

deceleration is the value set in the position table.

2) If the ST* signal is turned ON again, the remaining movement is continued. The acceleration

is the value set in the position table.

Before

operation

Positioning

complete

state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Operation of actuator

Start signal

ST*

(PLCoMSCON)

LS* not

turned ON

Position sensing output

LS*

(MSCONoPLC)