IAI America MSCON User Manual

Page 128

Advertising
background image

3.4 Fieldbus

Type

Address Map

120

(ON = Applicable bit is “1”, OFF = Applicable bit is “0”)

Signal Type

Bit

Symbol

Contents

Details

Completed

Position No.

(Simple

Alarm Code)

16 bits

PM1 to

PM128

16-bit integer

The positioning complete position number is

output in a binary number once getting into the

positioning band after moving to the target

position.

In the case that the position movement has not

been performed at all, or during the movement,

“0” is output. Read it by turning PEND Signal

ON after movement.

The simple alarm code [refer to Chapter 8

Troubleshooting] is output while an alarm is

issued (ALM of Status Signal is ON).

3.7 (29)

b15

EMGS

This signal turns ON during an emergency stop 3.7 (2)

b14

CRDY

This signal turns ON when the controller is

standing by.

3.7 (1)

b13

ZONE2

“ON” for the current position within the zone 2

set range

The zone range setting is necessary for the

parameter.

b12

ZONE1

“ON” for the current position within the zone 1

set range

The zone range setting is necessary for the

parameter.

3.7 (11)

b11

PZONE

Position zone (Invalid in Simple Direct Mode)

This signal turns ON when the current position

is inside the specified position zone.

3.7 (11)

b10

MODES

Teaching mode signal

(Invalid in Simple Direct Mode)

This signal is ON while the teaching mode is

selected.

3.7 (15)

b9

WEND

Position data import complete

(Invalid in Simple Direct Mode)

This signal turns ON when reading is complete.

3.7 (16)

b8

MEND

This signal turns ON when movement

command is complete, stopping with servo-on

and pressing is missed, and turns OFF when in

emergency stop with servo is OFF and while

CSTR Signal is ON

3.7 (21)

b7

BALM

Warning for absolute battery voltage drop

This signal turns ON with battery voltage drop

3.7 (22)

b6

Unavailable

b5

PSFL

This signal turns ON when the actuator missed

the load in push-motion operation.

3.7 (20)

b4

SV

This signal turns ON when operation standby is

complete (Servo is ON).

3.7 (5)

b3

ALM

This signal is ON while an alarm is generated.

3.7 (3)

b2

MOVE

This signal is ON while in movement.

3.7 (8)

b1

HEND

This signal turns ON at home return complete

and is kept unless the home position is lost due

to a fact such as an alarm.

3.7 (6)

P

LC

In

pu

t

Status Signal

b0

PEND

This signal turns ON at positioning complete

and is kept ON during a stop with the servo

ON, but does not turn ON when pressing

operation is failed.

3.7 (9)