8 control signals for positioner 2 mode – IAI America MSCON User Manual

Page 125

Advertising
background image

3.4 Fieldbus

Type
Address Map

117

3.4.8 Control Signals for Positioner 2 Mode

This is the operation mode with the position No. set up. The operation is to be made with the

position data set in the position table. This is a mode that the indication of the target position

and the monitoring of the current value are removed from Positioner 1 Mode.

The settable No. of position data items is max 256 points.

The main functions of MSCON capable to control in this mode are as described in the following

table.

ROBO cylinder function

{

: Direct control

ٌ

: Indirect control

u

: Disabled

Remarks

Home-return operation

{



Positioning operation

{



Speed and

acceleration/deceleration

setting

ٌ

Pitch feeding (Incremental)

ٌ

Pressing operation

ٌ

Speed change during

movement

ٌ

Operation at different

acceleration and

deceleration

ٌ

These items must be

set in the position

data.

Pause

{



Zone signal output

{



PIO pattern selection

u



(1) PLC Address Composition

(m is PLC input and output top word address for each axis number)

PLCĺMSCON (PLC Output)

MSCONĺPLC (PLC Input)

Indicated Position No.

m

Completed Position No.

(Simple Alarm Code)

m

Control Signal

m+1

Status Signal

m+1

[Refer to Section 3.4.2 for the address maps for each Fieldbus.]


CompoNet and MECHATROLINK are not applicable for this mode.