Chapter 7 Parameter

258

[14] Creep sensor input polarity (Parameter No.20)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

20 Creep Sensor Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

Even though the actuator with long stroke requires time to home-return if the power is shut at a

point far from the home position, the required time can be improved with using the creep

sensor.

The actuator moves at the creep speed (100mm/s or less) until a creep sensor signal is

detected, upon which the actuator will decelerate to the home return speed.

Creep sensor is an option for the line axis type.

This parameter is set properly prior to the shipment according to the specification of the

actuator.

Mechanical end

Home-return speed

Creep Speed

Creep Sensor

Actuator decelerates when creep sensor signal is detected

Power is turned ON here.

Set Value

Description

0

Not to use

1

Input is a contact

2

Input is b contact

[15] Servo ON input disable (Parameter No.21)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

21 Servo ON Input Disable Selection

FPIO

-

0: Enabled

1: Disabled

0

This parameter defines whether the servo ON input signal is disabled or enabled.

When the servo ON input signal is disabled, the servo is turned ON as soon as the controller

power is turned ON.

Set this parameter to “1” if servo ON/OFF is not provided.

Set Value

Description

0

Enabled (Use)

1

Disabled (Does not use)