2] speed change during the movement, Sample use, Liquid injection unit – IAI America MSCON User Manual

Page 191

Advertising
background image

3.8 C

ontrol and functions of Input and output signals of Remote I/O Mode

183

[2] Speed change during the movement

„

Sample use

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Gain

set

Stop

mode

0

1

150.00

250.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

0.00

50.00

0.20

0.20

0

0

100.00

0.00

0.00

0

0

0

0

3

0.00

100.00

0.20

0.20

0

0

0.10

0.00

5.00

0

0

0

0

„

Control method

The speed of the actuator can be changed while it moves. Positions are used by the number of

speeds. The method of controlling the operation to each position is the same as that described

in [1] Positioning.

The example below describes the case of 2 speeds:

1) In this example, the speed is changed while the actuator moves from the position of 150mm

to the position of 0mm. At first, set the positioning to the target position at the first speed in

position No.2. In the positioning width, set the distance from the speed change position to

the target position. The value is set to 100mm in the example. Thus, for position No.2,

positioning complete signal PEND is turned ON at the position before the target position by

100mm.

2) Set the positioning to the target position at the second speed in position No.3.

3) Start position No.2. Then start position No.3 successively when PEND in position No.2 is

turned ON. In normal positioning, position data specified later has always a priority over

position data specified earlier. Thus, the operation in position No.3 is started on the way of

the operation in position No.2.

In this example, the target positions No.2 and 3 are equal with each other. They may not be the

same. However, setting the target positions to be equal with each other allows the distance

from the speed change position to the target position to be known easily.

To increase in the number of speed change steps, add a position number and operation

sequence, set the speed change position in the positioning width and operate the actuator

continuously.

Liquid injection unit

The unit inserts nozzles into containers, injects liquid, and

moves the nozzles upward so that they may not be contact

with the liquid surfaces.

Positioning complete width at position 2

Stop

status

Position 1

Acceleration

Velocity

Time

Position 2 input

Start signal

input (moving

start)

Moving

comp.

Positioning

completion

signal output

Positioning

completion

signal output

Start signal

input (moving

start)

Position 3 input

Acceleration

Deceleration

Position 3

Position 2

2)

3)

1)

4)

5)

6) 7)

100mm/sec

50mm/sec

2)

3)

1)

4)

5)

6)

7)

Advertising