3.1 Basic Operation

63

Ɣ Operation Mode Available

7 types of operation modes are available to select from. The settings are to be established

with Gateway Parameter Setting Tool.

Shown below are the outline.

Operation

Pattern

Contents

Overview

Positioner 1

In Positioner 1 Mode, 256

points of position data can

be registered at the

maximum and is able to stop

at the registered positions.

Monitoring of the current

position is also available.

Simple Direct

Mode

In Simple Direct Mode, the

target position can be

indicated directly by

inputting a value. Monitoring

of the current position is also

available.

Those other than the target

position are to be indicated

in the position table, and the

setting can be done for 256

points at maximum.

Communication with Fieldbus

Dedicated Cable

100V/200V AC

+24V

Target Position

Target Position No.

Control Signal

PLC

Current Position

Completed Position No.

Status Signal

Electric Cylinder

Direct Indication

Mode

Direct Indication 2

Mode

The target position, speed

acceleration/deceleration

and pressing current limit

can be indicated with

inputting a number.

Monitoring of not only the

current position, but also the

current speed and indicated

current are available.

In Direct Indication 2 Mode,

anti-vibration control is

available instead of JOG

operation.

+24V

100V/200V AC

Target Position
Positioning Width
Speed
Acceleration/Deceleration
Push %
Control Signal

PLC

Current Position

Current Value

(Command Value)

Current Speed

(Command Value)
Alarm Code

Status Signal

Communication with Field Network

Dedicated Cable

Electric Cylinder

Position 2 Mode

This is the operation mode

of the position data of 256

points at maximum set in the

position table. The

monitoring of the current

position is not available

This mode is that the

transferred data is reduced

from Positioner 1 Mode.

+24V

100V/200V AC

Target Position No.

Control Signal

PLC

Completed Position No.

Status Signal

Communication with Fieldbus

Dedicated Cable

Electric Cylinder

Position 3 Mode

This is the operation mode

of the position data of 256

points at maximum set in the

position table. The

monitoring of the current

position is not available

This is the mode to control

with the minimized number

of signals to perform the

positioning operation by

reducing the amount of sent

and received data from

Positioner 2 Mode.

+24V

100V/200V AC

Target Position No.

Control Signal

PLC

Completed Position No.

Status Signal

Communication with Fieldbus

Dedicated Cable

Electric Cylinder