3.4 Fieldbus

Type

Address Map

128

3.4.11 About Commands (Position Data Read/Write and Alarm Axis Read)

By sending a specific code to a specific address, the position data reading and writing, and the

reading of the axis number that an alarm was issued and the alarm code can be performed.

Caution: • The command cannot be used in MECHATROLINK.

• It is not necessary to use commands in Simple Indication Mode because no

position data is to be used in it.



Shown below is the table to indicate the assignment of each signal.

(1) PLC Address Composition

(n is PLC input and output top address.)

PLCĺMSCON (PLC Output)

MSCONĺPLC (PLC Input)

Demand Command

n+2

Response Command

n+2

Data 0

n+3

Data 0

n+3

Data 1

n+4

Data 1

n+4

Data 2

n+5

Data 2

n+5

Data 3

n+6

Data 3

n+6

[Refer to Section 3.4.2 for the address maps for each Fieldbus.]

(2) Demand Command List

Class

Code

Description

Handshaking

0000

H

Demand command cleared

Write Position Data

1000

H

Writing of target position

1001

H

Writing of pressing width

1002

H

Writing of speed

1003

H

1004

H

Unavaillable

1005

H

Writing of acceleration

1006

H

Writing of deceleration

1007

H

Writing current limit at pressing

1008

H

Unavaillable

Read Position Data

1040

H

Reading of target position

1041

H

Reading of pressing width

1042

H

Reading of speed

1043

H

1044

H

Unavaillable

1045

H

Reading of acceleration

1046

H

Reading of deceleration

1047

H

Reading of current limit at pressing

1048

H

Unavaillable

Error Information Monitoring

4000

H

Acquiring alarm-issued axis

4001

H

Acquiring alarm code