4 fieldbus type address map – IAI America MSCON User Manual

Page 87

Advertising
background image

3.4 Fieldbus

Type
Address Map

79

y

MSCON Output ĺ PLC Input (n is PLC input top word address from MSCON)

(Note 1)

PLC

Input Area

Simple

Direct

Mode

Positioner 1

Mode

Direct

Indication

Mode

Direct

Indication

Mode 2

Positioner 2

Mode

Positioner 3

Mode

Remote I/O

Mode

Details

n

Gateway Status 0

n+1

Gateway Status 1

3.4.3

n+2

Response Command

n+3

Data 0

n+4

Data 1

n+5

Data 2

n+6

Data 3

MSCON

Gate

wa

y

R

es

po

ns

e

A

re

a

n+7

Occupied Area

(Note 2)

3.4.11

n+8

Completed

Position No./

Simple

Alarm ID

(Axis No.0)

Status

Signal/

Completed

Position

(Axis No.0)

Assignment

Area for

Axis No.0

n+9

Current Position

(Axis No.0)

Current

Position

(Axis No.0)

Current

Position

(Axis No.0)

Status

Signal

(Axis No.0)

Assignment

Area for

Axis No.1

Assignment

Area for

Axis No.1

n+10

Completed Position No./

Simple Alarm ID

(Axis No.0)

Assignment

Area for

Axis No.2

Assignment

Area for

Axis No.2

n+11

Status Signal

(Axis No.0)

Command

Current

(Axis No.0)

Command

Current

(Axis No.0)

Assignment

Area for

Axis No.1

Assignment

Area for

Axis No.3

Assignment

Area for

Axis No.3

n+12

Current

Speed

(Axis No.0)

Current

Speed

(Axis No.0)

Assignment

Area for

Axis No.4

Assignment

Area for

Axis No.4

n+13

Occupied

Area

(axis No.0)

Occupied

Area

(Axis No.0)

Assignment

Area for

Axis No.5㩷

Assignment

Area for

Axis No.5

n+14

Alarm Code

(Axis No.0)

Alarm Code

(Axis No.0)

n+15

Assignment

Area for

Axis No.1

Status

Signal

(Axis No.0)

Status

Signal

(Axis No.0)

n+16

to

n+23

Assignment

Area for

Axis No.1

Assignment

Area for

Axis No.1

C

on

ne

ct

ed

A

xe

s

R

es

po

ns

e

A

re

a

n+24

to

n+71

Assignment

Area for

Axis No.2

Assignment

Area for

Axis No.2

and later

Assignment

Area for

Axis No.2

and later

Assignment

Area for

Axis No.2

and later

3.4.4

to

3.4.10

Note1: For CC-Link, n and n+1 are for input and output bit addresses, and n+8 is for the top

address of data register.

Note2: This is the domain occupied unconditionally. Therefore, this domain cannot be used for

any other purpose.

٧

In the case of CC-Link

Station Type: Ver.2 Remote device station

Extended Cyclic Setting/Occupied Station Number Setting:

Register the information of the occupations displayed on Gateway Parameter Setting Tool to the

master unit. Connection cannot be established if information other than occupation is set.

[Refer to 3.2 Initial Setting.]

Caution: Ɣ Remote I/O Mode cannot be used together with other modes.

Ɣ Only Positioner 3 Mode and Remote I/O Mode are available to be selected in

MECHATROLINK and CompoNet. (CompoNet occupies 32 bytes no matter of

the number of axes.)