4 fieldbus type address map – IAI America MSCON User Manual

Page 134

Advertising
background image

3.4 Fieldbus

Type

Address Map

126

(3) I/O signal assignment

The controller's I/O port signal varies depending on the parameter No.25 setting.

[Refer to 3.8 Remote I/O Mode]

Set the parameter No.25 of MSCON

Positioning mode

Teaching mode

256-point mode

0

1

2

Category

Port

No.

Symbol

Signal Name

Symbol

Signal Name

Symbol

Signal Name

0

PC1

PC1

PC1

1

PC2

PC2

PC2

2

PC4

PC4

PC4

3

PC8

PC8

PC8

4

PC16

PC16

PC16

5

PC32

Specified position No.

PC32

Specified position No.

PC32

6

MODE

Teaching mode

command

PC64

7

JISL

Jog/inching switching

PC128

Specified position No.

8

Unavailable

JOG+

+Jog

Unavailable

9

BKRL

Brake release

JOG-

-Jog

BKRL

Brake release

10

Unavailable

Unavailable

Unavailable

11

HOME

Home return

HOME

Home return

HOME

Home return

12

*STP

Pause

*STP

Pause

*STP

Pause

13

CSTR

Positioning start

CSTR/

PWRT

Positioning start/

Position data import

command

CSTR

Positioning start

14

RES

Reset

RES

Reset

RES

Reset

PLC outputψ

MSCON input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0

PM1

PM1

PM1

1

PM2

PM2

PM2

2

PM4

PM4

PM4

3

PM8

PM8

PM8

4

PM16

PM16

PM16

5

PM32

Completed position No.

PM32

Completed position No.

PM32

6

MOVE

Moving signal

MOVE

Moving signal

PM64

7

ZONE1

ZONE1

MODES

Teaching mode signal

PM128

Completed position

No.

8

PZONE/

Z0NE2

Position zone/

Zone 2

PZONE/

ZONE1

Position zone/

Zone 1

PZONE/

ZONE1

Position zone/

Zone 1

9

Unavailable

Unavailable

Unavailable

10

HEND Home return completion

HEND

Home return

completion

HEND

Home return

completion

11

PEND

Positioning completion

signal

PEND/

WEND

Positioning completion

signal/Position data

import complete

PEND

Positioning

completion signal

12

SV

Operation preparation

end

SV

Operation preparation

completion

SV

Operation preparation

end

13

*EMGS

Emergency stop

*EMGS

Emergency stop

*EMGS

Emergency stop

14

*ALM

Alarm

*ALM

Alarm

*ALM

Alarm

MSCON output

ψ

PLC input

15

*BALM

Absolute battery

voltage drop alarm

*BALM

Absolute battery

voltage drop alarm

*BALM

Absolute battery

voltage drop alarm

(Note): “*” in codes above shows the signal of the active low.

(Reference) Signal of Active Low

A signal of active low is a signal that the input signal is processed when it is turned OFF, output signal is ordinarily on while

the power is ON, and turns OFF when the signal is output.