3.7

Control and functions of Input and output signals of Modes other than Remote I/O Mode

Power Supply and Cutof

f

166

1)

2)

3)

4)

5)

6)

7)

8)

9)

12)

11)

13)

14)

n1

v1

m1

t1

s1

n2

n3

v2

v3

m2

m3

t2

s2

s3

twcsON

twcsOFF

tpdf

n1

Target Position

Data Setting

(PLC→MSCON)

Positioning Width Data

/Pressing Width Data

(PLC→MSCON)

Speed Data

(PLC→MSCON)

Acceleration/

Deceleration Data

(PLC→MSCON)

Pressing Current Limit

(PLC→MSCON)

Push-motion

Specification

PUSH

(PLC→MSCON)

Push Direction

Specification

DIR

(PLC→MSCON)

Positioning Start

CSTR

(PLC→MSCON)

Position Complete/

Pressing and a Miss

PEND / PSFL

(MSCON→PLC)

Current Position

(MSCON→PLC)

Moving

MOVE

(MSEP→PLC)

Actuator Movement

Pressing Operation

Actuator Movement

Normal Positioning

10ms or less

10ms or less

n2

Push

Target Position

Positioning Width

Positioning Width

0ms or more

Target Position

t3

10)

10)



To turn ON TwcsON, have an interval of time more than 10ms.

To turn OFF TwcsOFF, have an interval of time more than 10ms.

Tdpf = Yt+10+Xt (minimum value) to Yt+10+Xt+7 (maximum value)