IAI America MSCON User Manual

Page 116

Advertising
background image

3.4 Fieldbus

Type

Address Map

108

Signal Type

Bit

Symbol

Contents

Details

b15

BKRL

Brake release

ON: Brake release, OFF: Brake activated

3.7 (17)

b14

INC

Incremental Command

ON: Relative position movement command,

OFF: Absolute position movement command

3.7 (26)

b13

DIR

Push direction specification

ON: Movement against home position,

OFF:Movement toward home position

3.7 (19)

b12

PUSH

Push-motion specification

ON: Pressing operation, OFF: Positioning operation

3.7 (18)

Select the servo gain parameter set

number to be used

GSL1 GSL0

Gain Set

b11

GSL1

Servo Gain

Parameter

Set Select 1

OFF

OFF

Gain Parameter

Set 0 Select

OFF

ON

Gain Parameter

Set 1 Select

ON

OFF

Gain Parameter

Set 2 Select

ON

ON

Gain Parameter

Set 3 Select

b10

GSL0

Servo Gain

Parameter

Set Select 0

3.7 (25)

b9

Unavailable

b8

JOG+

+Jog

ON: Movement against home position, OFF: Stop

3.7 (12)

b7

JOG- -Jog

ON: Movement toward home position, OFF: Stop

3.7 (12)

b6

JVEL

Jog-speed/inch-distance switching

OFF : Use the setting values of Parameter No.26

JOG Speed and No.48 Inching Distance in

MSCON

ON : Use the setting values of Parameter No.47

JOG Speed 2 and No.49 Inching Distance in

MSCON

3.7 (13)

b5

JISL

Jog/inching switching

ON: Inching, OFF: Jog

3.7 (14)

b4

SON

Servo ON command

ON: Servo ON, OFF: Servo OFF

3.7 (5)

b3

RES

Reset

A reset is performed when this signal turns ON.

3.7 (4)

b2

STP

Pause

ON: Pause, OFF: Pause Release

3.7 (10)

b1

HOME

Home return

Home-return command with this signal ON, command

carried on till complete even if the signal is turned OFF

on the way

3.7 (6)

P

LC

O

ut

pu

t

Control Signal

b0

CSTR

Positioning Start

Movement command executed with this signal ON,

command carried on till complete even if the signal is

turned OFF on the way

3.7 (7)