IAI America MSCON User Manual
Page 189
![background image](/manuals/350327/189/background.png)
3.8 C
ontrol and functions of Input and output signals of Remote I/O Mode
181
[Shortcut control of rotary actuator of multi-rotation specification]
(1) Set of shortcut selection
The shortcut selection can be made valid/invalid by Parameter No.80 “rotation axis shortcut
selection”. If the shortcut selection is made valid, the actuator can be moved only in a single
direction.
[Operation Examples]
Position No.
Position
1
0
2
90
3
180
4
270
Enter position data assuming 1q =
1mm.
(Example) 1.2 is assumed as 1.2q.
For operation in the order of positions 1o2o3o4, the actuator is moved differently whether
the shortcut selection is valid or invalid.
y
When shortcut selection is invalid:
y
When shortcut selection is valid:
Position No.1
Position No.2
Position No.3
Position No.4