background image

Chapter 2 Wiring

41

[3] Emergency Stop Circuit

It is the example of circuit layout when an emergency switch of the teaching pendant is used to

the emergency stop circuit of the equipment.

Note 1: When the teaching pendant is not connected, S1 and S2 become short-circuited

inside the controller.

Note 2: When the motor power must be disconnected externally for safety category

compliance, apply a safety rated contactor between L and N.

Note 3: The rating for the emergency stop signal (EMG-) to turn ON/OFF at contact CR1 is

24V DC and 30mA.

Note 4: For CR1, select the one with coil current 0.1A or less.

+24V

0V

CR1

Emergency

stop reset

switch

Emergency

stop switch

Emergency stop switch

for the teaching pendant

(Note 1)

S1

S2

CR1

(Note 4)

MC1

(Note 1)

MSCON

L

N

+24V

Motor Power Cutoff Relay

Motor power supply

AC100V

AC200V

CR1

(Note 3)

MC1

(Note 2)

EMG+

EMG–

MSCON

Second unit

CR1

System I/O Connector

Motor Power Input Connector

System I/O Connector

SIO Connector

SIO Connector

S1

S2

(Note 1)

L

N

+24V

Motor Power Cutoff Relay

AC100V

AC200V

CR1

(Note 3)

MC1

(Note 2)

EMG+

EMG–

Motor Power Input Connector

Motor power supply

Advertising