Chapter 2 Wiring

53

2.3.5 Connection of Regenerative Resistance Unit

Connect the regenerative resistance unit with a cable enclosed with it referring to the figure

below. The cable to connect with MSCON and that to connect each regenerative resistance

unit differ to each other in the model code.

Regenerative Resistance Unit Connector Model

Remarks

Cable Side

1-178128-3

Controller Side

1-178138-5

Pin

No.

Signal Name

Contents

Applicable Cable

1

RB+

Regenerative Resistance +

2

RB-

Regenerative Resistance -

3

PE

Protective Ground Terminal

Dedicate cable

enclosed with

regenerative

resistance unit

Refer to the table below to connect the necessary number of units.

Total Wattage for Motors of 6 Axes

Actuator horizontally

oriented

Actuator vertically oriented

No. of Connected

Regenerative Resistance

Units

to 450

to 200

0

to 900

to 600

1

-

to 800

2

-

to 900

3

Caution : The number of connectable units is a reference for when operation is made

under the following condition;

[Condition] When 1,000mm of back and forth operation is made under the

actuator maximum speed, acceleration/deceleration 0.3G and

rated load with the duty 50%.

In some operational conditions, gateway alarm “0A2 Motor Power Voltage

Error” or “0AB Estimated Regenerative Discharge Power Excess” may be

generated, and it may require more regenerative resistor that described in

the table above. In such cases, add more regenerative resistance units.

However, please note the number of maximum connectable regenerative

resistance units is 4. It is not effective even with connection more than

necessary. Consider to change the operational conditions (to reduce the

load) or to use a higher specification actuator.

1) CB-SC-REU010

2) CB-ST-REU010

(2nd unit or later)

Front view of

connector on

controller side

RB+

RB-

PE