3.6 Power Supply and Cutof

f

146

(3) Power supply status LED

The conditions of the control power and motor driving source can be checked on the power

supply status LEDs in the front panel.

{

: Illuminating, ×: OFF

Name

Status Display

Color

Description

{

Red

Turned ON when motor driving source is ON

(Keeps ON even if the driving source is turned OFF as long

as an electric charge is remained)

CHARGE

×

Motor driving source OFF

{

Green Control power source operating in normal condition

{

Orange

Control power source error (Turns ON when overvoltage is

applied or internal overcurrent is detected)

Condition remained until power shut down

PWR

×

Control power supply OFF

Warning (Electric Shock Caution)

Do not touch the terminals for motor power input connector and motor connector while

it is ON. You may get an electric shock in case the electric charge is still remained in

the capacitor even after the driving source is turned OFF.