IAI America MSCON User Manual

Page 265

Advertising
background image

Chapter 7 Parameter

257

[10] Dynamic brake (Parameter No.14)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

14 Dynamic Brake

FSTP

-

0: Disabled

1: Enabled

1

This parameter defines whether the dynamic brake is enabled or disabled while the actuator is

at standstill.

Normally it need not be changed.

[11] Pause input disable selection (Parameter No.15)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

15 Pause Input Disable Selection

FPIO

-

0: Disabled

1: Enabled

0

This parameter defines whether the pause input signal is disabled or enabled.

If a pause operation is not needed, set the parameter to “1” and an operation becomes

available without controlling the pause signal.

Set Value

Description

0

Enabled (Use)

1

Disabled (Does not use)

[12] Home position check sensor input polarity (Parameter No.18)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

18 Home Position Check Sensor

Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

The home sensor is an option.

Set Value

Description

0

Standard specification

(sensor not used)

1

Input is a contact

2

Input is b contact

[13] Overrun sensor input polarity (Parameter No.19)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

19 Overrun Sensor Input Polarity

AIOF

-

0 to 2

In accordance

with actuator

This parameter is set properly prior to the shipment according to the specification of the

actuator.

Set Value

Description

0

Standard specification without sensor

1

Over travel detection sensor input is a contact

2

Over travel detection sensor input is b contact