IAI America MSCON User Manual

Page 156

Advertising
background image

3.7

Control and functions of Input and output signals of Modes other than Remote I/O Mode

Power Supply and Cutof

f

148

(5) Servo ON command (SON)

PLC Output Signal

Operation ready (SV)

PLC Input Signal

Positioning complete (PEND) PLC Input Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

{

{

{

{

{

{

Servo ON command SON is the input signal making the servo motor of the actuator operable.

1) Once the Servo ON is executed and the operation comes available, Operation Ready SV

starts turned ON. The positioning complete signal PEND turns ON at the same time. Also,

the axis status LED (SV) on the front panel corresponding for the axis number turns ON in

green.

2) With the power being supplied, then controller cannot be operated while the SV signal

remains OFF. If SON Signal is turned OFF during the actuator operation, the actuator

decelerates and stops with the emergency stop torque, servo turns OFF, and the motor goes

into the free-run condition. The brake (option) is of release-in-excitation type. Therefore, the

brake gets released when excitation is ON and the brake works (locks) when excitation is

OFF.

Dynamic Brake

Brake Excitation

Lock

Release

It may differ due to operation condition

and load condition.

SON

SV

20ms

100ms

PEND

(Note)

Lock

Release

(MSCON → PLC)

(PLC → MSCON)

(MSCON → PLC)

(Note 1)

Note 1: PEND would not turn ON in the pause condition.

Advertising