Configuring the Ultra3000 Drive Chapter 3

Understanding the Service
Information Window

The Service Information window looks like this.

Use the Service Information window to:

Modify the size of an offline drive file before transferring the configuration
to an online drive.

Display and monitor service information about the drive.

Display the firmware revision of the drive.

The following parameters and status apply to the Service Information window:

Parameter

Description

Drive Size:

Change the power rating in kW of an offline drive.
Invalid no drive selected
0.5 500W 230V 2098-DSD-005-x
1 1kW 230V 2098-DSD-010-x
2 2kW 230V 2098-DSD-020-x
3 3kW 230V 2098-DSD-030-x
7.5 7.5kW 230V 2098-DSD-075-x
15 15kW 230V 2098-DSD-150-x
3(HV) 3kW 460V 2098-DSD-HV030-x
5(HV) 5kW 460V 2098-DSD-HV050-x
10(HV) 10kW 460V 2098-DSD-HV100-x
15(HV) 15kW 460V 2098-DSD-HV150-x
22(HV) 22kW 460V 2098-DSD-HV220-x

Status

Description

Drive Model

The model number of the drive. This is the number you selected
from the Select New Drive dialog box after executing the Insert
Ultra3000 command.

PICS Number

A unique identifier assigned to each drive.

Firmware Version

The revision of the selected On-Line drive’s firmware in the format
XX.YY, where:
XX = major revision
YY = minor revision

Time In Service

Total time (hours and minutes) the drive has been powered-up.