Chapter 4 Configuring the Ultra5000 Drive

Understanding the
Oscilloscope Window

The Properties window for the Oscilloscope looks like this

Use the Oscilloscope window to trace one of four drive signals by:

Configuring the oscilloscope by selecting a the drive signal to trace.

Executing commands that run the oscilloscope's tracing function
continuously or in response to the configured trigger.

Monitoring the oscilloscope as it traces the selected drive signal.

The Oscilloscope window has these parameters and commands associated with it.

Parameter Description

Channel A, B, C and D

Input Signal

Assign a drive signal to the selected Channel (A, B, C or D) from
the Channel Setup dialog box that opens when you click the
down arrow to the right of this input box.
Note: The resolution of this signal may be confusing if Velocity
Feedback is selected. See the topic Velocity Motor Feedback
Resolution for information on how resolution is derived for
various motor and feedback combinations.

Scale Type

Scale Types are:
Auto
Manual
Same As ChA (available for Channels B,C and D)
Same As ChB (available for Channels C and D)
Same as ChC (available for Channel D only)