Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 187

Advertising
background image

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

189

Configuring the Ultra5000 Drive Chapter 4

Scale

The amplitude of the selected channel input signal that can be
displayed between gridlines of the oscilloscope, in the units of
the drive signal. It is dependent on the signal selected. If the
Scale is left at its default value of 0, The data is autoscaled to fit
the graph.
Note: Visible only if Scale Type is Manual.

Offset

The trace offset for the selected Channel Input. Its range
depends on the signal selected. A value of zero places the zero
value of the signal at the middle grid line. A nonzero offset
shifts the trace up or down so that the offset value is positioned
at the middle grid line.
Note: Visible only if Scale Type is Manual.

Sweep Parameters

Sample Period

The time, in milliseconds, between samples that constitute a
trace. The horizontal resolution of the oscilloscope is 128
samples. (For example, selecting a sample period of 1.0 ms
results in 128 mS of data being displayed.)
Note: The Sample Period has a resolution of 0.125 ms.

Samples per Division

Number of samples per division. For example, 32 samples per
division results in 4 horizontal divisions.

Trigger Source

The drive signal that sets off the trigger and begins tracing the
selected channel signal, upon the occurrence of the Trigger
Mode at the Trigger Threshold. See Input Signal for a list of
available Trigger Source selections.

Trigger Mode

Event trigger for oscilloscope tracing:
Immediate: begins tracing immediately when the selected

drive signal becomes active.

Rising Edge: begins tracing when the selected Trigger Source

value increases above the Trigger Threshold value.

Falling Edge: begins tracing when the selected Trigger Source

value decreases below the Trigger Threshold value.

Trigger Threshold

The value of the Trigger Source drive signal that begins tracing.
Trigger Mode selections are:
Rising Edge
Falling Edge.

Trigger Status

The current status of the oscilloscope trigger:
Idle
Awaiting Trigger
Collecting Data

Oscilloscope Display

Y-axis Labels

Labels to display on the y-axis:
Default – One reference point for each channel is displayed.
Channel A
Channel B
Channel C
Channel D

Legend

Displays the color of the trace for each input signal or channel.
Click the color rectangles displayed in the legend to modify a
color.

Parameter Description