Understanding the indexing window – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual
Page 64
![background image](/manuals/580375/64/background.png)
66
Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 3 Configuring the Ultra3000 Drive
Understanding the Indexing
Window
The Properties window for Indexing looks like this.
Use the Indexing window to:
•
configure up to sixty-four indexes (0
–
63), and
•
open the Indexing Control Panel where you can:
– start and stop execution of the index command
– start and stop homing
– enable or disable a drive, and
– monitor the execution of an index.
An index controls drive operation by executing preconfigured motion
commands.
An index controls drive operation when Operating Mode is set to Indexing, in
the Ultra3000 Drive window. The drive uses the index whose number (0
–
63)
reflects the cumulative binary values of the Preset Select Lines 0, 1, 2, 3, 4 and 5,
that are selected in the Digital Inputs window.