252

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 5 Configuring the Kinetix 3 Drive

The following commands can be executed for a Motor window of an online
Kinetix 3 drive.

Customize the Motor window for your Kinetix 3 drive by selecting one or more
of these commands:

Click Show Status to display or hide the Status pane.

Click Show Commands to display or hide the Commands pane.

Click Setup to open the

Monitor Setup Window

on page 276, where you

can customize the status display for this window.

Click Revert to return parameter settings to the values they held when you
opened this window.

Cth(w-e)

Thermal capacitance from the winding to the encoder, in Watt-
seconds per degree centigrade (Watt-second/°C).
Note: This setting applies and is visible only if Software
Protection is set to Yes.

Rth(w-a)

Thermal resistance from the winding to ambient, in degrees
centigrade/watt (°C/Watt).
Note: This setting applies and is visible only if Software
Protection is set to Yes.

Cth(w-a)

Thermal capacitance from the winding to ambient, in Watt-
seconds per degree centigrade (Watt-second/°C).
Note: This setting applies and is visible only if Software
Protection is set to Yes.

Command

Description

Refresh Data

Reads the motor definition information from the motor database
and reapplies it to the drive.
Note: This command is useful when a motor definition in the
motor database has been changed.

Save Parameters

Saves the values currently selected in flash memory for the
selected online drive and all of its children.

Status (Continued)

Description