Configuring the Ultra3000 Drive Chapter 3

If a Preset Select Line is not assigned to a digital input, the Preset Select Line is
considered inactive.

The Follower window has no associated status or direct commands. The Follower
window has these parameters:

Click Revert to return parameter settings to the values they held when you
opened this window.

TIP

Binary values for an active digital input's Preset Select Lines 3, 4 and 5
do not apply to this calculation.

Parameter

Description

Slew Limit Enable

Indicate whether the drive's Slew Limit is:
Active
Inactive

Slew Limit

The drive acceleration limit when the master changes speed. It
has a range of 0…2,147,483,647 counts per second

2

.

Gear Ratios (Master:Follower)

Preset 0 – 7

Eight preset drive gear ratios. Each preset value represents the
ratio of the counts of master input counts to motor encoder
counts.
The master input counts value has a range of 1…32,767 counts,
and the motor encoder counts value has a range of
- 32,767…32,767 counts.