Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 291

Advertising
background image

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

293

Configuring the Kinetix 3 Drive Chapter 5

E.036 E.druot

Drive Overtemperature

Excessive heat exists in
the drive

Verify cooling fan

operation (only 2071-
A10, 2071-A15)

Check tuning.

Reduce acceleration

rate.

Reduce duty cycle

(ON/OFF) of
commanded motion.

Increase time

permitted for motion.

Use larger drive and

motor.

E.037 E.ACoFF

AC Line Loss

Poor quality power

Increase Ride Through
time.

Attempted to enable
drive without main
power active.

Apply main power before
enabling drive.

Phase connection
missing

Remove power and verify
all physical connections.

Fault Delay parameter is
set too short

Increase the Fault Delay
parameter setting.

E.053 E.ACoFF User

Parameter

Initialization Error

Error in parameter
memory storage

Re initialize

parameter.

Reset drive to factory

defaults.

E.054 E.oFSEt

Current Feedback Offset Defective

hardware

Replace

drive.

E.055 E.CHSUN User

Parameter

Checksum Error

Checksum error

Confirm and reset

parameter.

Reset drive to factory

defaults.

E.056 E.CPUFt Watchdog

Time-out

Excessive system noise

Verify wiring and

installation methods.

Defective hardware
Replace drive.

E.057 E.HWArE

PWM Hardware Error

Defective hardware

Contact A-B.

E.058 E.rAnGE

User Parameter Range
Error

Range of parameter is
invalid

Enter parameter with

value(s) within range.

Reset drive to factory

defaults.

E.060 E.dInIt Drive

Initialization Error

Hardware error

Replace drive.

E.075 E.SHtoL Shunt

Overload

Protection

Power at regenerative
resistor exceeds the
permitted value

Adjust motion profile

to stay within the
range of the
regenerative resistor.

Shunt resistor is

disconnected or
damaged

Verify resistance of

shunt resistor.

Status Description Possible Cause

Suggested Action

Advertising