Thermal:
Integral Thermostat:
Check when motor has a built-in thermostat.
Software Protection:
Check when thermal protection through software is desired.
Thermal Properties
Rth(w-e)
0.00001 to 32767.999 C/W winding-to-encoder thermal
resistance
Cth(w-e)
0.0039 to 8388607 W-s/C winding-to-encoder thermal
capacitance
Rth(w-a)
0.00001 to 32767.999 C/W winding-to-ambient thermal
resistance
Cth(w-a)
0.0039 to 8388607 W-s/C winding-to-ambient thermal
capacitance
Command
Description
Close
Closes the Linear Motor window with the parameters as
entered.
Parameter Description