Auxiliary feedback diagnostics – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 90

Advertising
background image

92

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 3 Configuring the Ultra3000 Drive

Auxiliary Feedback Diagnostics

Use the Auxiliary Feedback Diagnostics window to verify the operation of the
auxiliary feedback signals.

The Auxiliary Feedback Diagnostics window has these parameters, status, and
commands:

Parameter

Description

Test Distance

The encoder count Value for the Test Distance. The value should
be scaled according to the existing logic for scaling the Position
- Motor Feedback.
Testing is started and stopped by clicking the appropriate Test
button:
Start Test
Stop Test

Status

Description

Test Status

Possible displays include:
Idle
Test in Progress
Test Success
Test Failure

Test Results

Possible displays include:
blank (nothing to report),
Test Aborted by User
Test Distance Reached
Marker Found
Wiring Changes Recommended
Feedback Resolution Error
Encoder Alignment Error

Position - Auxiliary

Displays the Counts/Electrical Cycle recorded during the test.

A

ON indicates the presence of the master encoder's A output
signal.

B

ON indicates the presence of the master encoder's B output
signal.

Command Description

Start Test

Turns testing ON.

Stop Test

Turns testing OFF.