43

Configuring the Ultra3000 Drive Chapter 3

Operation Mode

The drive's command source.
Note: An online drive must be disabled before you can edit its
Operation Mode parameter.
Selections include:

Analog Current Input: a +/- 10 volt analog input provides the

current command.

Analog Position: a +/- 10 volt analog input provides the position

command.

Analog Velocity Input: a +/- 10 volt analog input provides the

velocity command.

Follower: Auxiliary Encoder: a quadrature encoder provides a

position command signal input to the drive.

Follower: Step/Direction Input: Step and Direction inputs

provide a position command signal input to the drive.

Follower: Step Up/Step Down Input: Step Up and Step Down

inputs provide a position command signal input to the drive.

Indexing: (only for Indexing drives) Up to 64 indexes can be

configured in the Indexing window. The combination of Preset
Select Lines 0, 1, 2, 3, 4 and 5, in the Digital Inputs window,
determines the Index (0 – 63) that is selected.

Refer to Understanding the Digital Inputs Window on page 95

for more information about how to assign a Preset Select Line
to a Digital Input.

Preset Current: a preset Current provides the current command.

Up to 8 Preset Current values can be set in the Preset window.
The combination of Preset Select Lines 0, 1 and 2 in the Digital
Inputs window, determines the Preset Current (0 – 7) that is
selected.

Refer to Understanding the Digital Inputs Window on page 95

for more information about how to assign Preset Select Line
functions to a Digital Input.

Preset Position: a preset Position provides the position

command. Up to 8 Preset Position values can be set in the
Preset window. The combination of Preset Select Lines 0, 1 and
2 in the Digital Inputs window, determines the Preset Position
(0 – 7) that is selected.

Refer to Understanding the Digital Inputs Window on page 95

for more information about how to assign a Preset Select Line
to a Digital Input.

Preset Velocity: a Preset Velocity provides the velocity

command. Up to 8 Preset Velocity values can be set in the
Preset window. The combination of Preset Select Lines 0, 1 and
2 in the Digital Inputs window, determines the Preset Velocity
(0 – 7) that is used for the velocity command.

Refer to Understanding the Digital Inputs Window on page 95

for more information about how to assign Preset Select Line
functions to a Digital Input.

Operation Mode Override

The connected drive's command source that is used when the
Operation Mode Override input is active. The Operation Mode
Override input is assigned to a digital input in the Digital Inputs
window.
Note: See

Operation Mode

, above, for an explanation of the

available selections.

Parameter Description