Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 288

Advertising
background image

290

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 5 Configuring the Kinetix 3 Drive

Errors are displayed on the drive's Status display with an E. prefix. The remaining
segments alternate between a three-digit error code and a five-digit text message.

Status Description Possible Cause

Suggested Action

Note: The value of status that are ‘ON’ = 1. The value of status that are OFF = 0.

E.004 E.Ntrot

Motor Overtemperature

Motor thermal switch
trips due to:
High motor ambient

temperature,

Excessive current, or
Both high temperature

and excessive current

Operate within (not

above) the continuous
torque rating for the
ambient temperature.

Lower ambient

temperature, or
increase motor
cooling.

Motor wiring error

Check motor wiring.

Incorrect motor selection Verify the proper motor

has been selected.

E.005 E.PNFt

IPM Error

Motor cables shorted

Verify the continuity of
motor power cable and
connector.

Motor winding shorted
internally

Disconnect the motor
power cables from the
motor. If the motor is
difficult to turn by hand,
it may need to be
replaced.

Drive temperature too
high,

Check for clogged

vents or a defective
fan.

Ensure cooling is not

restricted by
insufficient space
around the drive.

Drive has a bad IPM
output, short circuit, or
overcurrent

Verify ambient

temperature is not too
high.

Operate within the

continuous power
rating.

Reduce acceleration

rates.

Remove all power and

motors connections,
then perform a
continuity check from
the DC bus to the U, V,
and W motor
terminals. If continuity
exists, check for wire
fibers between
terminals, or send
drive in for repair.

Advertising