Chapter 5 Configuring the Kinetix 3 Drive

The following commands can be executed for a Kinetix 3 Drive window that is in
the On-Line Drives branch. These commands are explained in these sections.

Customize the window for your Kinetix 3 Drive branch by selecting one or more
of these commands:

Click Show Status to display or hide the Status pane.

Click Show Commands to display or hide the Commands pane.

Click Setup button to open the

Refer to Monitor Setup Window on

page 276

, where you can customize the status display for this window.

Click Revert to return parameter settings to the values they held when you
opened this window.

Velocity Control Panel Window

The Properties window for the Velocity Control Panel looks like this.

Command

Description

Velocity Control Panel

Opens the Velocity Control Panel window.

Refer to Velocity Control Panel Window on page 234

for more

information about how to set a drive's velocity command and
monitor its motor velocity or current.

Reset Drive

Resets, or reboots, the hardware and firmware for a drive.

Reset to Factory Setting

Resets a drive's parameters by reinitializing them to factory
default settings. Stored faults and the Time in Service clock
remain unchanged

Save Parameters

Saves the current working values as power-up values in the
flash memory for the selected online drive and all of its children.

Setup Wizard

Provides a quick way to perform the minimal configuration
necessary for a new Kinetix 3 drive.

Refer to Using the Setup Wizard on page 236

for more

information about this wizard.