226

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 5 Configuring the Kinetix 3 Drive

You can edit parameters for both an online and an offline drive. However, you
can monitor status, and execute direct commands only for a Kinetix 3 drive in the
On-Line Drives branch. Direct commands are so named because they execute
directly through the Ultraware interface.

The following parameters apply to the Kinetix 3 Drive window.

Parameter Description

Name

The name of the selected Kinetix 3 drive must:
be at least one, but not more than thirty-two, characters in

length

be unique within its branch of the tree
not contain a space or backslash (\), forward slash (/), colon (:),

asterisk (*), question mark (?), double quote (“), greater than
symbol (>), less than symbol (<) or pipe (|)

AC Line Loss Check Select

The type of AC line loss:
Enable: drive monitors the AC inputs for line loss by a:

50 - 400W Drive and enables a single-phase open check.
0.8 - 1.5kW Drive and enables a 3-phase open check.

Disable: drive ignores the checking for AC line loss.
Single-phase input: Drive monitors the AC inputs for line loss by

a 0.8 - 1.5kW Drive and enables a 3-phase open check.

Auto Motor Iden

The type of Automatic Motor Identification:
Disabled: Causes the drive to use the motor parameters supplied

for the Motor Model selected below.

Enabled: Causes the drive to read motor parameters from an

intelligent encoder.

Motor Model

Predefined motor types.

Command Polarity

ATTENTION: Changing this parameter
will cause instability if the drive is in a
stable position or in a velocity loop.

The type of polarity of the command signal:

Normal: The sign of the external command signal to the drive is

not inverted.

Inverted: The sign of the external command signal to the drive is

inverted.

Displayed Units

The unit of measure for position, velocity, and acceleration:
Metric: units for rotary motors are counts (position), rpm

(velocity), revolutions per second

2

(acceleration); units for linear

motors are meters (position), meter per second (velocity), and
meter per second

2

(acceleration).

English: units for rotary motors are counts (position), rpm

(velocity), revolutions per second

2

(acceleration); units for linear

motors are inches (position), inches per second(velocity), and
inches per second

2

(acceleration).

User: measurements in terms defined by the user in the Units

section, below.