Torque Constant

(Only for rotary motors) The sinusoidal force constant, in
Newton meters/Ampere (N-m/A).

Force Constant

(Only for linear motors) The sinusoidal force constant, in
Newtons/Ampere (N/A).

Inertia

Rotor inertia, in Kilogram-centimeter squared (kg-cm²).

Mass

(Only for linear motors) Rotor mass, in Kilograms (kg).

Poles/Revolution

The number of motor poles per revolution.

Electrical Cycle

(Only for linear motors) The distance between motor poles, in
Meters.

Integral Limits

Indicates whether the motor provides built in feedback for travel
limits:
Yes
No

Electrical

Rated Voltage

Voltage rating of the motor in Volts

Resistance

The phase-to-phase resistance of the motor stator, in
milliHenries (mH).

Inductance

The phase-to-phase inductance of the motor stator, in
milliHenries (mH).

Flux Saturation at 1/8, 1/4, 3/
8, 1/2, 5/8, 3/4, 7/8 and 8/8
(100%) of the motor peak
current.

Eight separate status values that specify the level of flux
saturation in the motor at the specified fraction of maximum
current level. A value of 1.0 indicates no flux saturation.

Ratings

Maximum Speed

Maximum motor speed, in revolutions/minute (rpm).

Intermittent Current

Maximum intermittent current of the motor in Amperes.

Continuous Current

Continuous current rating of the motor in Amperes.

Feedback

Encoder

The encoder type:
Incremental
Sine/Cosine
SRS/SRM (only displayed offline). When a motor with this

encoder type is selected for an online drive, Auto Motor Iden
is set to true, and the Encoder indicates Sine/Cosine.)

Commutation

The type of commutation:
Brush
Trapezoidal
Sinusoidal

Sinusoidal Startup

The type of startup for sinusoidal commutation:
Self-Sensing
Hall Inputs
Serial (only displayed offline). When a motor with this start-

up type is selected for an online drive, Auto Motor Iden is set
to true, and the Sinusoidal Startup indicates Self-Sensing.)

Hall Input Offset

Hall Input offset, from standard Rockwell Automation
orientation, in electrical degrees.

Lines/Revolution

Encoder lines per revolution.
Note: This parameter is visible only if the Type is Rotary.

Lines/Meter

Encoder lines per meter of travel.
Note: This parameter is visible only if the Type is Linear.