Chapter 5 Configuring the Kinetix 3 Drive

2. Click OK.

The word Unassigned appears in the selected Channel in the Oscilloscope
window.

Understanding Kinetix 3
Status Displays

Status for the Kinetix 3 drive are displayed in the Monitor window. Signals from
oscilloscope channels may be used as data sources for the status table.

Status

Description Oscilloscope

Input Trigger

Oscilloscope
Output Trigger

Monitor Analog

Output

Signal

Fault Detail
Channel

Drive Status

Analog Command -
Velocity

Refer to Understanding the
Analog Window on page 237

X

X

X

X

X

Analog Command -
Current

Refer to Understanding the
Analog Window on page 237

X

X

X

X

X

Bus Voltage

The current measure of DC Bus
voltage.

X

X

X

Commutation Angle -
Degrees

Reports the position within the
motor electrical cycle in
degrees from -180 to 180
degrees.

X

X

X

X

X

Enabled

ON indicates the power stage
of the drive is enabled. As a
precondition, either software
or hardware enable must be
active, and the drive cannot
have any faults.

X

Fault Warning

Refer to Understanding the
Kinetix 3 Drive Branch on
page 225

.

X

Firmware Version

Refer to Understanding the
Service Information Window
on page 297

X

Motor Temperature

Reports the percentage of the
Motor Temperature Trip value,
that is based on the motors
continuous current rating,
thermal characteristics, and
time.
The Motor Temperature is an
indication of the level of
utilization of the motor's
current capability. When the
Motor Temperature reaches
100% a Motor Filter fault
occurs.

X

X

X

Current Operating
Mode

Refer to Understanding the
Kinetix 3 Drive Branch on
page 225

X