Chapter 4 Configuring the Ultra5000 Drive

The following status is displayed by default.

The Properties window for the Service Information branch of older Ultra5000
drives, firmware revision 1.1.5 or earlier, displays these information.

Status

Description

Drive Model

The model number of the drive. (Only displayed for online drives).
This number is set at the factory.

PICS Number

A unique identifier assigned to each drive.

Firmware Version

The revision of the firmware on the drive.

Boot Firmware Version

The revision of the boot firmware on the drive.

FPGA Version

The revision of the firmware containing the FPGA image and the burn
in self test code.

Rated Current

The maximum current the drive can continuously produce without
faulting.

Peak Current

The maximum current the drive can on an intermittent basis.

Service Clock

The hours and minutes the drive has been powered-up.

Sequencer Loads

Frame Load 1

A visual graph showing the percentage of available CPU time (125
microseconds = 100%) actually used in each Frame Load (1 - 4).

Frame Load 2

Frame Load 3

Frame Load 4

Frame 1 Peak Load

The Peak Frame Load (1 - 4) since the peaks were reset.

Frame 2 Peak Load

Frame 3 Peak Load

Frame 4 Peak Load

Status

Description

Drive Type

The type of Ultra5000 drive:
Invalid: prevents the drive from being enabled.
2098-IPD-005
2098-IPD-010
2098-IPD-020
2098-IPD-030
2098-IPD-050
2098-IPD-100
2098-IPD-150
2098-IPD-HV030
2098-IPD-HV050
2098-IPD-HV100
2098-IPD-HV150
2098-IPD-HV220
Note: the drive uses the selection to:
decide when to signal an IPM Filter fault, and
properly scale the feedback from the power stage of the drive. The

output of the velocity regulator stage of the drive is limited by the
selected drive type.