Motor feedback diagnostics – Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 88

Advertising
background image

90

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 3 Configuring the Ultra3000 Drive

Motor Feedback Diagnostics

Use the Motor Feedback Diagnostics window to verify a motor's position
feedback signals.

The Motor Feedback Diagnostics window has these parameters, status, and
commands:

S1 Connection

Possible values are:
“ “ (blank), nothing to report
No Changes Required
Move to S1 Input
Move to S2 Input
Move to S3 Input
Move to A Input
Move to B Input
Move to U Input
Move to V Input
Move to W Input

S2 Connection

S3 Connection

A Connection

B Connection

U Connection

W Connection

Hall Offset

Offset in 30 degree increments (0, 30, 60, …330).

Command

Description

Start Test

Turns the oscilloscope trigger ON.

Stop Test

Turns the oscilloscope trigger OFF.

Parameter

Description

Test Distance

The encoder count Value for the Test Distance. The value should
be scaled according to the existing logic for scaling the Position
- Motor Feedback.

Statuses

Description

Test Status

Indicates the current status of the Motor Feedback diagnostics.
Possible displays include:
Idle
Test in Progress
Test Success
Test Failure

Test Results

Possible displays include:
“ “ (blank), nothing to report,
Test Aborted by User
Test Distance Reached
Marker Found
Wiring Changes Recommended
Feedback Resolution Error
Encoder Alignment Error

Position - Motor Feedback

Displays the Counts/Electrical Cycle recorded during the test.

A

ON indicates a master encoder A output signal is present.

B

ON indicates a master encoder B output signal is present.

Start Test

Turns testing ON.

Stop Test

Turns testing OFF.

Statuses